Type: | Ph.D.-level, Open University Language: English |
|
|
|
|
Prerequisite: 53327
|
|
Recommended semester: 7th - 9th semester
|
Scope and form: Lectures and 2 laboratory exercises.
|
Examination: Oral exam (13-scale)
|
Participant limitation: max. 16
|
|
|
|
Department: Department of Electric Power Engineering
|
Aim: To supplement a knowledge of traditional and advanced high voltage cable technology and to give the students experience in application of methods for dimensioning and diagnosis of these cable types.
|
Contents: The topics treated are:
- Design and application of paper/oil and XLPE cables, thermal aspects under different load conditions
- Superconducting cables
- Partial discharges in high voltage cables
- Exercise 1: Diagnosis of 10kV DTU-cable.
- Theoretical approach on the formation of space charges in high voltage cables
- Exercise 2: Measurement of space charges
|